Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 6years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
HDR-100 Switching Power Supply | |||||
Project | Technical indicators | ||||
output | DC voltage | 12V | 15V | 24V | 48V |
rated current | 4.5A | 6.13A | 3.83A | 1.92A | |
rated power | 54W | 92W | 92W | 92.2W | |
pipple and noise | 120mVp-p | 120mVp-p | 150mVp-p | 240mVp-p | |
Voltage ADJ.range | 10.8~13.8v | 15~17v | 24~25.5v | 48~48.7v | |
Voltage tolerance Note.3 | ±2% | ±1% | ±1% | ±1% | |
load adjustment rate | ±1% | ||||
liner adjustment rate | ±1% | ||||
input | voltage range | 85-264VAC 47Hz~63Hz(120VDC~370VDC) | |||
efficiency | 88% | 89% | 90% | 91% | |
Frequency range | 47-63Hz | ||||
Ac current | 3A/115VAC 1.6A/230VAC | ||||
Inrush current(typ.) | Cold start35A/115VAC 70A/230VAC | ||||
pretection characteristics |
overload protection | Hiccup mode when output voltage<50%,recovers automatically after fault condition is removed.Constant current limiting within 50%-100%rated output voltage,recovers automatically after fault condition is removed. | |||
Over voltage protection | Protection type:Shutdown o/p voltage,re-power on to recover | ||||
Environment | Working temp | -30ºC~70ºC(refer to "Derating Curve") | |||
Working humidity | -20ºC~+90ºC;RH non-condensing | ||||
security | Withstand voltage | I/P-O/P:4KVAC | |||
Isolation resistor | I/P-O/P:10M Ohms/500VDC/25ºC/70%RH | ||||
other | size | 70*90*54.5mm(L*W*H) | |||
Net weight/gross weight | 0.27Kg |