Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 6 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
DR-45 45W Rail Type Switching Power Supply
|
|
|
|
|
|
|||||
Project
|
|
Technical index
|
|
|
|
|||||
Output
|
DC voltage
|
12V
|
|
24V
|
|
|||||
|
Rated current
|
3.5A
|
|
2A
|
|
|||||
|
Rated power
|
42W
|
|
48W
|
|
|||||
|
Ripple and noise
|
120mV
|
|
150mV
|
|
|||||
|
Voltage accuracy
|
±1%
|
|
|
|
|||||
|
Output voltage regulation range
|
±10%
|
|
|
|
|||||
|
Load adjustment rate
|
±1%
|
|
|
|
|||||
|
Linear adjustment rate
|
±1%
|
|
|
|
|||||
Input
|
Voltage range
|
85-264VAC 47Hz63Hz (120VDC370VDC)
|
|
|
|
|||||
|
Efficiency (typical)
|
82%
|
|
84%
|
|
|||||
|
Working current
|
1A 110VAC 0.5A 220VAC
|
|
|
|
|||||
|
Impulse current
|
110VAC 15A 220VAC 30A
|
|
|
|
|||||
|
Start, rise, hold time
|
100ms30ms21ms 110VAC/100ms30ms100ms 220VAC
|
|
|
|
|||||
Protect
|
overload protection
|
≥ 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again
|
|
|
|
|||||
|
Short circuit protection
|
+VODrop to undervoltage point to close output
|
|
|
|
|||||
Environmental Science
|
Working temperature and humidity
|
-10+5020%90RH
|
|
|
|
|||||
|
Working temperature and humidity
|
-20+8510%95RH
|
|
|
|
|||||
Safety regulations
|
Withstand voltage
|
Input output: 3kVac: 0.5kvac for 1 minute
|
|
|
|
|||||
|
Isolation resistance
|
Input output, input shell, output shell: 500VDC / 100M Ω
|
|
|
|
|||||
Other
|
Size
|
78*93*56mm
|
|
|
|
|||||
|
Net/Gross weight
|
270/290g
|
|
|
|