Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 3 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
LRS-50 Switching Power Supply | |||||||
Project | Technical indicators | ||||||
output | DC voltage | 5V | 12V | 24V | 36V | 48V | |
rated current | 10A | 4.2A | 2.2A | 1.45A | 1.1A | ||
rated power | 50W | 50.4W | 52.8W | 52.2W | 52.8W | ||
pipple and noise | 80mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | ||
voltage regulation range | ±10% | ||||||
load regulation rate | ±1% | ||||||
liner adjustment rate | ±0.5% | ±0.5% | |||||
voltage range | 85-264VAC/120-373VDC 47Hz~63Hz | ||||||
input | working current | 0.95A/115VAC 0.56A/230VAC | |||||
Efficiency |
>82% | >86% | >88% | >89% | >90% | ||
start up time | 1000ms,30ms/230VAC 2000ms,30ms/115VAC (full load) | ||||||
leakage current | <1mA 240VAC | ||||||
pretection characteristics |
overload protection | ≥110%-130%type:protection mode:hiccup mode automatic recovery after abnormal conditions are removed |
|||||
overvoltage protectionn | ≥115%-145%Protection type:close the output,restart and automatically return to normal | ||||||
Environment | operating temperature,humidity | -30ºC~70ºC;20%~90RH | |||||
storage temperature,humidity | -40ºC~+85ºC;10%~95RH | ||||||
Pressure resistance | Input-output:4KVAC input-case:2KVA output-case:1.25KVAC duration: 1 minute | ||||||
security | Isolation impedance | Input-output and input-shell,output-shell:500VDC/100mΩ25ºC70%RH | |||||
other | size | 99*82*30mm(L*W*H) | |||||
Net weight/gross weight | 230g/246g |