Customization: | Available |
---|---|
Output Type: | Multiple |
Warranty: | 3 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Q-120 Switching Power Supply | ||||||||||||
Project | Q-120D | |||||||||||
Output channel | CH1 | CH2 | CH3 | CH4 | ||||||||
output | DC voltage | 5V | 15V | 24V | -12V | |||||||
rated current | 8A | 2.5A | 2A | 0.5A | ||||||||
rated power | 124W | 124W | 124W | 124W | ||||||||
Ripple and noise | <80MV | <120MV | <150MV | <80MV | ||||||||
voltage accuracy | ±2% | ±8%-3% | ±8% | ±5% | ||||||||
voltage regulation range | ±10% | |||||||||||
load adjustment rate | ±1% | ±3% | ±5% | ±2% | ||||||||
liner adjustment rate | ±0.5% | ±1% | ±1% | ±1% | ||||||||
input | voltage range | 85-132/480-264VAC 47Hz~63Hz(120VDC~370VDC) | ||||||||||
efficiency | >80% | >80% | >80% | >80% | ||||||||
operating current | <1.1A 110VAC <0.6A 220VAC | |||||||||||
impulse current | 110VAC 18A,220AC 45A | |||||||||||
start up time | 900ms,20ms,20ms:220VAC/800MS,20ms,10ms:115VAC | |||||||||||
leakage current | ≤1mA 240VAC | |||||||||||
protection characteristics |
overload protection | ≥105%-150%type:hiccup mode,automatic recovery after abnormal release | ||||||||||
short circuit protection | +VO drops to the undervoltage point and the output is closed the output +VO reset:power on again | |||||||||||
Environment | operating temperature,humidity | -10ºC~50ºC;20%~90RH | ||||||||||
storage temperature,humidity | -20ºC~+85ºC;10%~95RH | |||||||||||
security | Withstand voltage | Input-output:1.5KVAC input-case:1.5KVAC output-case:1.5KVAC duration:for 1 minute | ||||||||||
Isolation resistor | Input-output and input-shell,output-shell:500VDC/100mΩ | |||||||||||
other | size | 199*110*50mm(L*W*H) | ||||||||||
Net weight/gross weight | 616.3g/654.3g |