| Customization: | Available |
|---|---|
| Output Type: | Single |
| Warranty: | 3 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| MS-250 250W Switching Power Supply | |||||
| Project | Technical index | ||||
| Output | DC voltage | 5V | 12V | 24V | 48V |
| Rated current | 40A | 20.8A | 10.4A | 5.2A | |
| Rated power | 200W | 249.6W | 249.6W | 249.6W | |
| Ripple and noise | <50mV | <120mV | <150mV | <240mV | |
| Voltage accuracy | ±2% | ±1% | |||
| Output voltage regulation range | ±10% | ||||
| Load adjustment rate | <±0.5% | <±0.5% | <±0.5% | ||
| Linear adjustment rate | <±0.5% | ||||
| Input | Voltage range | 185-264VAC 47Hz~63Hz (254VDC~370VDC) | |||
| Efficiency (typical) | >82% | >84% | >84% | ||
| Working current | <2.5A 220VAC | ||||
| Impulse current | 220VAC 36A | ||||
| Start, rise, hold time | 200ms,50ms,20ms :220VAC | ||||
| Protect | overload protection | 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | |||
| Short circuit protection | +VODrop to undervoltage point to close output | ||||
| Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | |||
| Working temperature and humidity | -20ºC~+85ºC;10%~95RH | ||||
| Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | |||
| Leakage current | Input output 1.5KVAC <5mA | ||||
| Leakage current | Input output 220VAC <1mA | ||||
| Isolation resistance | Input output,Input - Housing, Output - Housing:500VDC/100MΩ | ||||
| Other | Size | 199*50*110mm(L*W*H) | |||
| Net Weight /Gross Weight | 0.72/0.78KG | ||||