| Customization: | Available |
|---|---|
| Output Type: | Single |
| Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency





| RSP-300W | ||||||
| Project | Technical indicators | |||||
| Rated power | 300W | |||||
| Peak power | 600W | |||||
| Rated input voltage | DC 12V | DC 24V | DC 48V | |||
| No load current | 0.3A | 0.1A | 0.5A | |||
| Output voltage | AC 100-240V±5% | |||||
| Output frequency | 50/60±1 Hz | |||||
| Under voltage alarm | 10.5±0.5V | 21±0.5V | 42V±1 | |||
| Under voltage protection | 9.5±0.5V | 20±0.5V | 40V±1 | |||
| Under pressure recovery | 13±0.5V | 24±0.5V | 48V±1 | |||
| High voltage alarm protection | 15.5±0.5V | 31±0.5V | 61V±1 | |||
| High pressure recovery | 14.8±0.5V | 29.5±0.5V | 59V±1 | |||
| DC voltage range | 9.55-15.5V | 19.8-30.27V | 40.2-60.4V | |||
| Output waveform | Pure sine wave | |||||
| Max conversion efficiency | 90% | |||||
| Standby power consumption | Input voltage rating,LOAD ,switch on,the inverter self-loss power around 5W | |||||
| Enter insurance | Built-in/(DC) DC short circuit protection | |||||
| USB | 5V/2.1A | |||||
| Warranty period | One year | |||||
| Over-temperature protection | ≥90ºC | |||||
| Recovery from overheating | ≤70ºC | Auto-restore AC output | ||||
| Short circuit protection | ≤0.5S cut down | No AC output,short-circuit failure after the automatic recovery of normal output | ||||
| Sensory load testing | When connected to ≤ load(e.g.electric appliance such as electric drill),it can work normally | |||||
| Resistance load test | When connected with ≤ load(such as incandescent bulb,heater),it can work normally | |||||
| Load superposition test | The first less than load input output,open the switch after normal operation,and then increase the load(load superposition power value,not greater than rated power),and arbitrary plug,the inverter can work properly | |||||
| Ambient humidity | Working condition:relative humidity 10%~90%(no condensation) Storage:relative humidity 5%~95%(no condensation) |
|||||
| Ambient temperature | The inverter can work normally at the temperature of-30ºC~60ºC | |||||
| Heat dissipation mode | Intelligent fan,temperature ≥45ºC on,≤40ºC off | |||||
| LED indicator light | Green indicator light(inverter output,normal operation);red indicator flashing alarm(under/overvoltage,overload,high temperature,short circuit) | |||||
| Protection function | Battery over/under voltage,overload,high temperature,ac short circuit protection(forward and reverse connection protection) | |||||
| Product display optional | No display/LED/LCF(one of three options) | |||||
| Circuit topology | High frequency chain | |||||
| Cooling mode | Intelligent air-cooled.built-in double bear sink block | |||||
| How to get electricity | 12V battery | 24V DC voltage | 48V DC voltage | |||
| Product dimensions | 19.5*11*5.5CM | |||||
| NET/gross weight of product | 1.85kg/1.05kg | |||||
| Quantity/weight packed | 12PCS/13.4kg | |||||