| Customization: | Available |
|---|---|
| Output Type: | Single |
| Warranty: | 6 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| EDR-120 Din Rail Switching Power Supply | ||||
| Project | Technical indicators | |||
| output | DC voltage | 12V | 24V | 48V |
| rated current | 10A | 5A | 2.5A | |
| rated power | 120W | 120W | 120W | |
| pipple and noise | <120MV | <120MV | <150MV | |
| voltage accurac | ±2% | ±1% | ±1% | |
| voltage regulation range | ±10% | |||
| load adjustment rate | ±1% | |||
| liner adjustment rate | ±0.5% | |||
| input | voltage range | 85-264VAC 47Hz~63Hz(120VDC~370VDC:By connectionAC/L(+),AC/N(-)enable DC input) | ||
| efficiency | >86% | >88% | >89% | |
| perating current | <2.25A 110VAC <1.3A 220VAC | |||
| impulse current | 110VAC 20A,220AC 35A | |||
| start up time | 500ms,70ms,32ms:110VAC/500MS,70ms,36ms:220VAC | |||
| leakage current | <1mA 240VAC | |||
| pretection characteristics |
overload protection | ≥105%-150%type:protection mode:hiccup mode automatic recovery after abnormal conditions are removed |
||
| overvoltage protectionn | When the output voltage is greater than 135%,the shutdown output will automatically recover after the abnormal condition is removed |
|||
| short circuit protection | +VO drops to the undervoltage point and the output is closed After the abnormal condition is removed,the power supply restarts and the automatic recovery is resumed |
|||
| environment | operating temperature,humidity | -10ºC~+60ºC;20%~90RH | ||
| storage temperature,humidity | -20ºC~+85ºC;10%~95RH | |||
| security | Withstand voltage | Input-output:1.5KAV input-case:1.5KAV output-case:0.5KAV duration:1 minute | ||
| Isolation resistor | Input-output and input-shell,output-shell:500VDC/100mΩ | |||
| other | size | 40*125*113mm(L*W*H) | ||
| Net weight/gross weight | 707g/750g | |||