LRS-75 Series 75W Switching Power Supply | |||||
Project | Technical index | ||||
Output | DC voltage | 5V | 12V | 24V | 48V |
Rated current | 14A | 6A | 3.2A | 1.6A | |
Rated power | 70W | 72W | 76.8W | 76.8W | |
Ripple and noise | 100mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | |
Ripple and noise | ±10% | ||||
Voltage accuracy |
±2.0% | ±1.0% | ±1.0% | ±1.0% | |
Linear adjustment rate | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load adjustment rate | ±1.0% | ±0.5% | ±0.5% | ±0.5% | |
Starting and rising time | 500ms,30ms/230VAC 500ms,30ms/115VAC(full load) | ||||
Retention time | 60ms/230VAC 12ms/115VAC(full load) | ||||
Input | Voltage range / frequency | 85-264VAC / 120-373VDC 47Hz~63Hz | |||
Efficiency (typical) | 86.50% | 89% | 90% | 91.50% | |
Working current | 1.4A/115VAC 0.85A/230VAC | ||||
Impulse current | Cold boot:65A/230VAC | ||||
Leakage current | <0.75mA 240VACTime | ||||
Protect | overload protection | 110%-130% Protection type: burping mode, automatic return to normal after removing abnormal conditions | |||
Overvoltage protection | ≥ 115% - 145% protection type: close output, restart and automatically return to normal | ||||
Environmental Science | Working temperature and humidity | -30ºC~+70ºC;20%~90RH | |||
Storage temperature and humidity | -40ºC~+85ºC;10%~95RH | ||||
Safety regulations | Withstand voltage | Input output: 4kvac input shell: 2kvac output shell: 1.25kvac for 1 minute | |||
Insulation impedance | Input output, input shell, output shell: 500VDC / 100M Ω 25 ºC 70% RH | ||||
Other | size | 99*97*30mm(L*W*H) | |||
Net weight / gross weight | 250g/272g |
Lrs-75 series 75W switching power supply
|
|
|
|
|
|
|||||
project
|
|
Technical index
|
|
|
|
|||||
output
|
DC voltage
|
5V
|
12V
|
24V
|
48V
|
|||||
|
Rated current
|
14A
|
6A
|
3.2A
|
1.6A
|
|||||
|
Rated power
|
70W
|
72W
|
76.8W
|
76.8W
|
|||||
|
Ripple and noise
|
100mVp-p
|
120mVp-p
|
150mVp-p
|
200mVp-p
|
|||||
|
Ripple and noise
|
±10%
|
|
|
|
|||||
|
Voltage accuracy
|
±2.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
|||||
|
Linear adjustment rate
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
|||||
|
Load adjustment rate
|
±1.0%
|
±0.5%
|
±0.5%
|
±0.5%
|
|||||
|
Starting and rising time
|
500ms30ms/230VAC 500ms30ms/115VAC(full load)
|
|
|
|
|||||
|
Retention time
|
60ms/230VAC 12ms/115VAC(full load)
|
|
|
|
|||||
input
|
Voltage range / frequency
|
85-264VAC / 120-373VDC 47Hz63Hz
|
|
|
|
|||||
|
Efficiency (typical)
|
86.50%
|
89%
|
90%
|
91.50%
|
|||||
|
Working current
|
1.4A/115VAC 0.85A/230VAC
|
|
|
|
|||||
|
Impulse current
|
Cold boot65A/230VAC
|
|
|
|
|||||
|
Leakage current
|
0.75mA 240VACTime
|
|
|
|
|||||
protect
|
overload protection
|
110%-130% Protection type: burping mode, automatic return to normal after removing abnormal conditions
|
|
|
|
|||||
|
Overvoltage protection
|
≥ 115% - 145% protection type: close output, restart and automatically return to normal
|
|
|
|
|||||
function
|
Working temperature and humidity
|
-30+7020%90RH
|
|
|
|
|||||
|
Storage temperature and humidity
|
-40+8510%95RH
|
|
|
|
|||||
Safety regulations
|
Withstand voltage
|
Input output: 4kvac input shell: 2kvac output shell: 1.25kvac for 1 minute
|
|
|
|
|||||
|
Insulation impedance
|
Input output, input shell, output shell: 500VDC / 100M Ω 25 70% RH
|
|
|
|
|||||
Other
|
size
|
99*97*30mm(L*W*H)
|
|
|
|
|||||
|
Net weight / gross weight
|
250g/272g
|
|
|
|