Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 3 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
EDR-120 Din Rail Switching Power Supply | ||||
Project | Technical indicators | |||
output | DC voltage | 12V | 24V | 48V |
rated current | 10A | 5A | 2.5A | |
rated power | 120W | 120W | 120W | |
pipple and noise | <120MV | <120MV | <150MV | |
voltage accurac | ±2% | ±1% | ±1% | |
voltage regulation range | ±10% | |||
load adjustment rate | ±1% | |||
liner adjustment rate | ±0.5% | |||
input | voltage range | 85-264VAC 47Hz~63Hz(120VDC~370VDC:By connectionAC/L(+),AC/N(-)enable DC input) | ||
efficiency | >86% | >88% | >89% | |
perating current | <2.25A 110VAC <1.3A 220VAC | |||
impulse current | 110VAC 20A,220AC 35A | |||
start up time | 500ms,70ms,32ms:110VAC/500MS,70ms,36ms:220VAC | |||
leakage current | <1mA 240VAC | |||
pretection characteristics |
overload protection | ≥105%-150%type:protection mode:hiccup mode automatic recovery after abnormal conditions are removed |
||
overvoltage protectionn | When the output voltage is greater than 135%,the shutdown output will automatically recover after the abnormal condition is removed |
|||
short circuit protection | +VO drops to the undervoltage point and the output is closed After the abnormal condition is removed,the power supply restarts and the automatic recovery is resumed |
|||
environment | operating temperature,humidity | -10ºC~+60ºC;20%~90RH | ||
storage temperature,humidity | -20ºC~+85ºC;10%~95RH | |||
security | Withstand voltage | Input-output:1.5KAV input-case:1.5KAV output-case:0.5KAV duration:1 minute | ||
Isolation resistor | Input-output and input-shell,output-shell:500VDC/100mΩ | |||
other | size | 40*125*113mm(L*W*H) | ||
Net weight/gross weight | 707g/750g |