D-30 30W Two Groups of Switching Power Supply | |||||
Project | D-30A | D-30B | |||
Output | Output channel | CH1 | CH2 | CH1 | CH2 |
DC voltage | 5V | 12V | 5V | 24V | |
Rated current | 4A | 1A | 2A | 1A | |
Current range | 0.5-5A | 0.1-1.5A | 0.5-2A | 0.1-1A | |
Rated power | 32W | 35W | |||
Ripple and noise | <50mV | <120mV | <50mV | <120mV | |
Voltage accuracy | ±2% | ±10% | ±2% | ±10% | |
Output voltage regulation range | CH1: ±10% | ||||
Load adjustment rate | ±1.5% | ±3.0% | ±1.5% | ±3.0% | |
Linear adjustment rate | ±0.5% | ±1.0% | ±0.5% | ±1.0% | |
Input | overload protection | 85-132VAC/176-264VAC 47Hz~63Hz (254VDC~370VDC) | |||
Efficiency (typical) | >78% | >81% | |||
Working current | <0.75A 110VAC <0.4A 220VAC | ||||
Impulse current | 110VAC 18A, 220VAC 45A | ||||
Start, rise, hold time | 500ms,30ms,50ms :220VAC/1200ms,30ms,10ms :115VAC | ||||
Protect | overload protection | 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | |||
Short circuit protection | +VO drops to undervoltage point, close output | ||||
Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | |||
Storage temperature and humidity | -20ºC~+85ºC;10%~95RH | ||||
Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | |||
Leakage current | 5mA at 1.5kVac input-output | ||||
Leakage current | Input output at 220VAC < 1mA | ||||
Isolation resistance | Input output, input shell, output shell: 500VDC / 100M Ω | ||||
Other | size | 129*98*38mm | |||
Net weight / gross weight | 400/430g | ||||
Remarks | Ripple and noise measurement method: use a 12 "twisted pair, and connect 0.1uF and 47uF capacitors in parallel at the terminal, and measure at 20MHz bandwidth. The efficiency is tested at an input voltage of 230VAC, rated load, and an ambient temperature of 25 ºC. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear regulation test method: under rated load from low voltage to high voltage test load regulation test method: from 0% - 100% rated load. The start-up time is measured under the cold start state. The quick and frequent switch on and off may increase the start-up time. When the operating altitude is higher than 2000m, the operating environment temperature needs to be reduced by 5 ºC / 1000m |