Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 6 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
HDR-60 Switching Power Supply | |||||
Project | Technical indicators | ||||
output | DC voltage | 5V | 12V | 24V | 48V |
rated current | 6.5A | 4.5A | 2.5A | 12.5A | |
rated power | 32.5W | 54W | 60W | 60W | |
pipple and noise | 80mVp-p | 120mVp-p | 150mVp-p | 240mVp-p | |
Voltage ADJ.range | 5~5.5v | 10.8~13.8v | 21.6~29v | 43.2~55.2v | |
Voltage tolerance Note.3 | ±2% | ±1% | ±1% | ±1% | |
load adjustment rate | ±1% | ||||
liner adjustment rate | ±1% | ||||
input | voltage range | 180-264VAC 47Hz~63Hz(120VDC~370VDC) | |||
efficiency | 85% | 88% | 90% | 91% | |
perating current | <2.25A 110VAC <1.3A 220VAC | ||||
impulse current | 110VAC 15A,220AC 30A | ||||
start up time | 100ms,30ms,21ms:110VAC/100MS,30ms,100ms:220VAC | ||||
leakage current | <1mA 240VAC | ||||
pretection characteristics |
overload protection | ≥105%-150%type:protection mode:hiccup mode automatic recovery after abnormal conditions are removed |
|||
short circuit protection | +VO drops to the undervoltage point and the output is closed After the abnormal condition is removed,the power supply restarts and the automatic recovery is resumed |
||||
Environment | Working temp | -30ºC~70ºC(refer to "Derating Curve") | |||
Working humidity | -20ºC~+90ºC;RH non-condensing | ||||
security | Withstand voltage | I/P-O/P:4KVAC | |||
Isolation resistor | I/P-O/P:10M Ohms/500VDC/25ºC/70%RH | ||||
other | size | 52.5*90*54.5mm(L*W*H) | |||
Net weight/gross weight | 190g |