DR-120 120W Din Rail Power Supply | ||||
Project | Technical index | |||
Output | DC voltage | 12V | 24V | |
Rated current | 10A | 5A | ||
Rated power | 120W | 120W | ||
Ripple and noise | <120mV | <150mV | ||
Voltage accuracy | ±2% | ±1% | ||
Ripple and noise | ±10% | |||
Load adjustment rate | ±1% | |||
Linear adjustment rate | ±0.5% | |||
Input | Voltage range / frequency | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
Efficiency (typical) | >86% | >88% | ||
Working current | <2.6A 110VAC <1.6A 220VAC | |||
Impulse current | 110VAC 20A, 220VAC 40A | |||
Leakage current | 500ms,70ms,32ms :110VAC/500ms,70ms,36ms :220VAC | |||
Protect | overload protection | 105%-150% Type:production mode:burp modde automatic recovery after the abnormal condition is lifted | ||
Overvoltage protection | Output Voltage>135% will be restored automatically after it is removed | |||
Short circuit protection | VO The output abnormal condition will be restored automatically after it is removed after the power is restarted | |||
Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
Storage temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
Safety regulations | Withstand voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P:0.5KVAC | ||
leakage current | <1mA/240VAC | |||
Insulation impedance | I/P-O/P, O/P-Shell, O/P-Shell :500VDC/100MΩ | |||
Other | size | 65.5*125.2*100mm | ||
Net weight / gross weight | 790/815g |
DR-60 60W Din Rail Power Supply
|
|
|
|
|
|
|||||
Project
|
|
Technical index
|
|
|
|
|||||
Output
|
DC voltage
|
12V
|
|
24V
|
|
|||||
|
Rated current
|
4.5A
|
|
2.5A
|
|
|||||
|
Rated power
|
54W
|
|
60W
|
|
|||||
|
Ripple and noise
|
120mV
|
|
150mV
|
|
|||||
|
Voltage accuracy
|
±1%
|
|
|
|
|||||
|
Ripple and noise
|
±10%
|
|
|
|
|||||
|
Load adjustment rate
|
±1%
|
|
|
|
|||||
|
Linear adjustment rate
|
±1%
|
|
|
|
|||||
Input
|
Voltage range / frequency
|
85-264VAC 47Hz63Hz (120VDC370VDC)
|
|
|
|
|||||
|
Efficiency (typical)
|
82%
|
|
84%
|
|
|||||
|
Working current
|
1.2A 110VAC 0.8A 220VAC
|
|
|
|
|||||
|
Shock Current
|
110VAC 15A 220VAC 30A
|
|
|
|
|||||
|
Start,Rise,Hold time
|
100ms30ms21ms 110VAC/100ms30ms100ms 220VAC
|
|
|
|
|||||
Protect
|
overload protection
|
105%-150% Type:production mode:burp modde automatic recovery after the abnormal condition is lifted
|
|
|
|
|||||
|
Short circuit protection
|
VO The output abnormal condition will be restored automatically after it is removed after the power is restarted
|
|
|
|
|||||
Environmental Science
|
Working temperature and humidity
|
-10+5020%90RH
|
|
|
|
|||||
|
Working temp.and humidity
|
-20+8510%95RH
|
|
|
|
|||||
Safety regulations
|
Pressure Resistance
|
O/P-I/P,I/P-O/P:3KVAC
|
|
|
|
|||||
|
Isolation Resistance
|
I/P-O/P O/P-Shell,O/P-Shell 500VDC/100MΩ
|
|
|
|
|||||
Other
|
size
|
78*93*56mm
|
|
|
|
|||||
|
Net weight / gross weight
|
270/290g
|
|
|
|