| WDR-75 Din Rail Switching Power Supply | ||||
| Project | Technical indicators | |||
| Output | DC voltage | 12V | 24V | 48V |
| Rated current | 6.25A | 3.13A | 1.56A | |
| Rated power | 75W | 175W | 75W | |
| Ripple and noise | <120mV | <2000mV | <200mV | |
| Voltage regulation range | ±10% | |||
| Voltage accuracy | ±1.5% | ±1% | ±1% | |
| Liner adjustment rate | ±0.5% | |||
| Load adjustment rate | ±1% | |||
| Input | Efficiency | >86% | >88% | >90% |
| Voltage range/frequency | 200-500VAC 47Hz~63Hz(120VDC~370VDC) | |||
| Impulse current | 400VAC 50A 230VAC 30A | |||
| Protection characteristics | Overload protection | When the rated output power is≥105%-150%type:protection mode:hiccup mode automatic recovery after abnormal conditions |
||
| Overoltage protection | When the output voltage is greater than 135%,the shutdown output will automatically recover after the abnormal condition is removed | |||
| Environment | operating temperature,humidity | -30ºC~80ºC;20%~90RH | ||
| storage temperature,humidity | -40ºC~+85ºC;10%~95RH | |||
| Security | Withstand voltage | Input-output:3KVAC input ground:1.5kvac output ground:0.5kvac duration: 1 minute | ||
| Isolation resistor | Input-output and input-shell,output-shell:500VDC/100mΩ | |||
| Other | Size | 32*125*97mm | ||
| Net weight/gross weight | 330g | |||