| 15W Ultra Slim Step Shape DlN Rail HDR - 15 series |
||||||||
| SPEClFlCATlON | ||||||||
| MODEL | HDR-15-5 | HDR-15-12 | HDR-15-15 | HDR-15-24 | HDR-15-48 | |||
| OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V | 48V | ||
| RATED CURRENT | 2.4A | 1.25A | 1A | 0.63A | 0.32A | |||
| CURRENT RANGE | 0 ~ 2.4A | 0 ~ 1.25A | 0 ~ 1A | 0 ~ 0.63A | 0 ~ 0.32A | |||
| RATED POWER | 12W | 15W | 15W | 15.2W | 15.4W | |||
| RlPPLE & NOlSE(max.) Note.2 | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 240mVp-p | |||
| VOLTAGE ADJ. RANGE | 4.5 ~ 5.5V | 10.8 ~ 13.8V | 13.5 ~ 18V | 21.6 ~ 29V | 43.2 ~ 55.2V | |||
| VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||
| LlNE REGULATlON | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||
| LOAD REGULATlON | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||
| SETUP, RlSETlME | 2000ms, 80ms/230VAC 2000ms, 80ms/115VAC at full load | |||||||
| HOLD UP TlME(TYP.) | 30ms/230VAC 12ms/115VAC at full load | |||||||
| lNPUT | VOLTAGE RANGE | 85 ~ 264VAC(277VAC operational ) 120 ~ 370VDC(390VDC operational ) | ||||||
| FREQUENCY RANGE | 47 ~ 63Hz | |||||||
| EFFlClENCY(TYP.) | 80% | 85% | 85.5% | 86% | 87% | |||
| AC CURRENT(TYP.) | 0.5A/115VAC 0.25A/230VAC | |||||||
| lNRUSH CURRENT(TYP.) | COLD START 25A/115VAC 45A/230VAC | |||||||
| PROTECTlON | OVERLOAD | 110 ~ 145% rated output power | ||||||
| Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed Constant current limiting within 50% ~100% rated output voltage, recovers automatically after fault condition is removed |
||||||||
| OVER VOLTAGE | 5.75 ~ 6.75V | 14.2 ~ 16.2V | 18.8 ~ 22.5V | 30 ~ 36V | 56.5 ~ 64.8V | |||
| Protection type : Shut offo/p voltage, clamping by zener diode | ||||||||
| ENVlRONMENT | WORklNG TEMP. | -30 ~ +70ºC(Refer to "Derating Curve") | ||||||
| WORklNG HUMlDlTY | 20 ~ 90% RH non-condensing | |||||||
| STORAGE TEMP., HUMlDlTY | -40 ~ +85ºC, 10 ~ 95% RH non-condensing | |||||||
| TEMP. COEFFlClENT | ±0.03%/ºC(0 ~ 50ºC)RH non-condensing | |||||||
| VlBRATlON | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along x,Y, Z axes; Mounting: Compliance to lEC60068-2-6 | |||||||
| OPERATlNG ALTlTUDE | 2000 meters | |||||||
| OVER VOLTAGE CATEGORY | ; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude up to 2000 meters | |||||||
| SAFETY | WlTHSTAND VOLTAGE | l/P-O/P:4kVAC | ||||||
| lSOLATlON RESlSTANCE | l/P-O/P:100M Ohms / 500VDC / 25ºC/ 70% RH | |||||||
| OTHERS | MTBF | 3724.3k hrs min. Telcordia SR-332(Bellcore); 1166.1k hrs min. MlL-HDBk-217F(25ºC) | ||||||
| DlMENSlON | 17.5*90*54.5mm(W*H*D) | |||||||
| PACklNG | 74g;160pcs/12.9kg/1.09CUFT | |||||||
| NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The ambient temperature derating of 3.5ºC/1000m with fanless models and of 5ºC/1000m with fan models for operating altitude higher than 2000m(6500ft). |
|||||||
| 60W Ultra Slim Step Shape DlN Rail HDR-60 series |
|||||||||
| SPEClFlCATlON | |||||||||
| MODEL | HDR-60-5 | HDR-60-12 | HDR-60-15 | HDR-60-24 | HDR-60-48 | ||||
| OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V | 48V | |||
| RATED CURRENT | 6.5A | 4.5A | 4A | 2.5A | 1.25A | ||||
| CURRENT RANGE | 0 ~ 6.5A | 0 ~ 4.5A | 0 ~ 4A | 0 ~ 2.5A | 0 ~ 1.25A | ||||
| RATED POWER | 32.5W | 54W | 60W | 60W | 60W | ||||
| RlPPLE & NOlSE(max.) Note.2 | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 240mVp-p | ||||
| VOLTAGE ADJ. RANGE | 5.0 ~ 5.5V | 10.8 ~ 13.8V | 13.5 ~ 18V | 21.6 ~ 29V | 43.2 ~ 55.2V | ||||
| VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||||
| LlNE REGULATlON | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||||
| LOAD REGULATlON | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||||
| SETUP, RlSETlME | 500ms, 50ms/230VAC 500ms, 50ms/115VAC at full load | ||||||||
| HOLD UP TlME(TYP.) | 30ms/230VAC 12ms/115VAC at full load | ||||||||
| lNPUT | VOLTAGE RANGE | 85 ~ 264VAC(277VAC operational ) 120 ~ 370VDC(390VDC operational ) | |||||||
| FREQUENCY RANGE | 47 ~ 63Hz | ||||||||
| EFFlClENCY(TYP.) | 85% | 88% | 89% | 90% | 91% | ||||
| AC CURRENT(TYP.) | 1.2A/115VAC 0.8A/230VAC | ||||||||
| lNRUSH CURRENT(TYP.) | COLD START 30A/115VAC 60A/230VAC | ||||||||
| PROTECTlON | OVERLOAD | 105 ~ 160% rated output power | |||||||
| Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed Constant current limiting within 50% ~100% rated output voltage, recovers automatically after fault condition is removed |
|||||||||
| OVER VOLTAGE | 5.75 ~ 6.75V | 14.2 ~ 16.2V | 18.8 ~ 22.5V | 30 ~ 36V | 56.5 ~ 64.8V | ||||
| Protection type : Shutdown o/p voltage, re-power on to recover | |||||||||
| ENVlRONMENT | WORklNG TEMP. | -30 ~ +70ºC (Refer to "Derating Curve") | |||||||
| WORklNG HUMlDlTY | 20 ~ 90% RH non-condensing | ||||||||
| STORAGE TEMP., HUMlDlTY | -40 ~ +85ºC , 10 ~ 95% RH non-condensing | ||||||||
| TEMP. COEFFlClENT | ±0.03%/ºC (0 ~ 50ºC )RH non-condensing | ||||||||
| VlBRATlON | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along x,Y, Z axes; Mounting: Compliance to lEC60068-2-6 | ||||||||
| OPERATlNG ALTlTUDE | 2000 meters | ||||||||
| OVER VOLTAGE CATEGORY | ; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude up to 2000 meters | ||||||||
| SAFETY | WlTHSTAND VOLTAGE | l/P-O/P:4kVAC | |||||||
| lSOLATlON RESlSTANCE | l/P-O/P:100M Ohms / 500VDC / 25ºC / 70% RH | ||||||||
| OTHERS | MTBF | 3524.8k hrs min. Telcordia SR-332(Bellcore); 927.6k hrs min. MlL-HDBk-217F(25ºC ) | |||||||
| DlMENSlON | 52.5*90*54.5mm(W*H*D) | ||||||||
| PACklNG | 190g;60pcs/13kg/0.91CUFT | ||||||||
| NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The ambient temperature derating of 3.5ºC/1000m with fanless models and of 5ºC/1000m with fan models for operating altitude higher than 2000m(6500ft). |
||||||||
| 85 ~ 100W Ultra Slim Step Shape DlN Rail HDR - 100 series |
||||||||
| SPEClFlCATlON | ||||||||
| MODEL | HDR-100-12 | HDR-100-15 | HDR-100-24 | HDR-100-48 | ||||
| OUTPUT | DC VOLTAGE | 12V | 15V | 24V | 48V | |||
| RATED CURRENT | 7.1A | 6.13A | 3.83A | 1.92A | ||||
| CURRENT RANGE | 0 ~ 7.1A | 0 ~ 6.13A | 0 ~ 3.83A | 0 ~1.92A | ||||
| RATED POWER | 85.2W | 92W | 92W | 92.2W | ||||
| RlPPLE & NOlSE(max.) Note.2 | 120mVp-p | 120mVp-p | 150mVp-p | 240mVp-p | ||||
| VOLTAGE ADJ.RANGE | 12 ~ 13V | 15 ~ 17V | 24 ~ 25.5V | 48 ~ 48.7V | ||||
| VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ||||
| LlNE REGULATlON | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||||
| LOAD REGULATlON | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||||
| SETUP,RlSETlME | 500ms, 60ms/230VAC 500ms, 60ms/115VAC at full load | |||||||
| HOLD UP TlME(TYP.) | 30ms/230VAC 12ms/115VAC at full load | |||||||
| lNPUT | VOLTAGE RANGE | 85 ~ 264VAC(277VAC operational ) 120 ~ 370VDC(390VDC operational ) | ||||||
| FREQUENCY RANGE | 47 ~ 63Hz | |||||||
| EFFlClENCY(TYP.) | 88% | 89% | 90% | 90% | ||||
| AC CURRENT(TYP.) | 3A/115VAC 1.6A/230VAC | |||||||
| lNRUSH CURRENT(TYP.) | COLD START 35A/115VAC 70A/230VAC | |||||||
| PROTECTlON | OVERLOAD | HDR-100 : 102 ~ 110% rated output power ; HDR-100-XXN : 105 ~ 150% rated output power | ||||||
| Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed Constant current limiting within 50% ~100% rated output voltage, recovers automatically after fault condition is removed |
||||||||
| OVER VOLTAGE | 14.2 ~ 16.2V | 18.8 ~ 22.5V | 30 ~ 36V | 56.5 ~ 64.8V | ||||
| Protection type : Shutdown o/p voltage, re-power on to recover | ||||||||
| ENVlRONMENT | WORklNG TEMP. | -30 ~ +70ºC(Refer to "Derating Curve") | ||||||
| WORklNG HUMlDlTY | 20 ~ 90% RH non-condensing | |||||||
| STORAGE TEMP.,HUMlDlTY | -40 ~ +85ºC, 10 ~ 95% RH non-condensing | |||||||
| TEMP. COEFFlClENT | ±0.03%/ºC(0 ~ 50ºC)RH non-condensing | |||||||
| VlBRATlON | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along x,Y, Z aXes; Mounting: Compliance to lEC60068-2-6 | |||||||
| OPERATlNG ALTlTUDE | 2000 meters | |||||||
| OVER VOLTAGE CATEGORY | ; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude up to 2000 meters | |||||||
| SAFETY | WlTHSTAND VOLTAGE | l/P-O/P:4kVAC | ||||||
| lSOLATlON RESlSTANCE | l/P-O/P:100M Ohms / 500VDC / 25ºC/ 70% RH | |||||||
| OTHERS | MTBF | 3271.9k hrs min. Telcordia SR-332(Bellcore); 856.5k hrs min. MlL-HDBk-217F(25ºC) | ||||||
| DlMENSlON | 70*90*54.5mm(W*H*D) | |||||||
| PACklNG | 0.27kg; 48pcs/13.74kg/0.96CUFT | |||||||
| NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Harmonic current test at 90% load for HDR-100-XXN. 5. The ambient temperature derating of 3.5ºC/1000m with fanless models and of 5ºC/1000m with fan models for operating altitude higher than 2000m(6500ft). |
|||||||
| 150W Ultra Slim Step Shape DIN Rail HDR - 1 5 0 series |
||||||||||
| SPECIFICATION | ||||||||||
| MODEL | HDR-150-12 | HDR-150-15 | HDR-150-24 | HDR-150-48 | ||||||
| INPUT | DC VOLTAGE | 12V | 15V | 24V | 48V | |||||
| RATED CURRENT | 115VAC | 10.2A | 8.55A | 5.31A | 2.72A | |||||
| 230VAC | 11.3A | 9.5A | 6.25A | 3.2A | ||||||
| RATED POWER | 115VAC | 122.4W | 128.3W | 127.4W | 130.6W | |||||
| 230VAC | 135.6W | 142.5W | 150W | 153.6W | ||||||
| RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | ||||||
| OUTPUT | VOLTAGE ADJ. RANGE | 10.8~ 13.8V | 13.5 ~ 18V | 21.6 ~ 29V | 43.2 ~ 55.2V | |||||
| VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ||||||
| LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||||||
| LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||||||
| SETUP, RISE TIME | 500ms, 60ms/230VAC 500ms, 60ms/115VAC at full load | |||||||||
| HOLD UP TIME (Typ.) | 30ms/230VAC 12ms/115VAC at full load | |||||||||
| INPUT | VOLTAGE RANGE | 85 ~ 264VAC (277VAC operational ) 120 ~ 370VDC (390VDC operational ) | ||||||||
| FREQUENCY RANGE | 47 ~ 63Hz | |||||||||
| EFFICIENCY (Typ.) | 89% | 89.5% | 90.5% | 90.5% | ||||||
| AC CURRENT (Typ.) | 3A/115VAC 1.6A/230VAC | |||||||||
| INRUSH CURRENT (Typ.) | COLD START 35A/115VAC 70A/230VAC | |||||||||
| PROTECTION | OVERLOAD | 105 ~ 135% rated output power | ||||||||
| Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed Constant current limiting within 50% ~100% rated output voltage, recovers automatically after fault condition is removed |
||||||||||
| OVER VOLTAGE | 14.2 ~ 16.2V | 18.8 ~ 22.5V | 30 ~ 36V | 56.5 ~ 64.8V | ||||||
| Protection type : Shutdown o/p voltage, re-power on to recover | ||||||||||
| ENVIRONMENT | WORKING TEMP. | -30 ~ +70ºC (Refer to "Derating Curve") | ||||||||
| WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||||
| STORAGE TEMP., HUMIDITY | -40 ~ +85ºC, 10 ~ 95% RH non-condensing | |||||||||
| TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 45ºC) RH non-condensing | |||||||||
| VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,Y, Z axes; Mounting: Compliance to IEC60068-2-6 | |||||||||
| OPERATING ALTITUDE | 2000 meters (Note 4 ) | |||||||||
| OVER VOLTAGE CATEGORY | ;According to EN62368 ,EN61558 , EN50178 ,EN60664- 1 , EN62477- 1;altitude up to 2000 meters | |||||||||
| SAFETY STANDARDS | IEC62368-1, UL62368-1, UL61010, TUV BS EN/EN61558-2-16, BS EN/EN61558-1, EACTPTC 004 approved; Design refer to BS EN/EN50178, TUV BS EN/EN62368-1 |
|||||||||
| SAFETY | WITHSTAND VOLTAGE | I/P-O/P:4KVAC | ||||||||
| ISOLATION RESISTANCE | I/P-O/P:100M Ohms / 500VDC / 25ºC/ 70% RH | |||||||||
| OTHERS | MTBF | 3046.3K hrs min. Telcordia SR-332 (Bellcore) ; 535.9K hrs min. MIL-HDBK-217F (25ºC) | ||||||||
| DIMENSION | 105*90*54.5mm (W*H*D) | |||||||||
| PACKING | 0.31Kg; 32pcs/11Kg/1.0CUFT | |||||||||
| NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The ambient temperature derating of 3.5ºC/1000m with fanless models and of 5ºC/1000m with fan models for operating altitude higher than 2000 (6500ft). 5. when the input voltage is 230VAC,delivers EMl Class B for radiated emission for the power supply; when the input voltage is 110VAC, delivers EMl Class A for radiated emission for the power supply. 6. Harmonic current test at 70% load . |
|||||||||